Part Numbers: ARND-4195, 2KBF 4199P002-B; Product Name: TMEIC CCD-C Control Board
Brand: TMEIC (Toshiba Mitsubishi-Electric Industrial Systems Corporation); Product Series: Industrial Inverter Control Series, engineered for TMEIC AC drive systems, undertaking core tasks of drive logic operation, signal conversion, and multi-equipment coordination control.
Product Status: Original New Unit (In Stock); Product Category: Industrial Automation Control Board, specialized in high-performance control and precise signal management of medium-voltage and high-voltage industrial drive equipment.
Core Applications: TMEIC TMdrive-MVe/TMdrive-LV series inverter systems, steel rolling equipment, marine propulsion systems, power generation units, industrial compressors, large-scale pumps, fans and other heavy-duty industrial scenarios requiring high-precision and stable drive control.
Core Features: Modular integrated design; High compatibility with TMEIC mainstream drive platforms; High-speed digital-analog hybrid signal processing; Advanced fault diagnosis and alarm function; Support for multiple industrial communication protocols; Industrial-grade anti-interference capability and wide temperature adaptation.
2. Electrical Specifications
2.1 Power Parameters
Power Supply: DC 24V ±10% (Industrial Standard); Rated Power Consumption: ≤15W (Typical Operation); Peak Power Consumption: ≤22W (During Startup and Load Peak).
Input Current: 0.6A (Typical, 24V DC), 1.2A (Peak, 24V DC); Standby Current: ≤50mA (24V DC, No Load).
2.2 Signal & Communication Parameters
Communication Interface: PROFIBUS DP, MODBUS RTU, Ethernet/IP (Optional); Data Transmission Rate: Up to 12Mbit/s (PROFIBUS DP), 100Mbit/s (Ethernet/IP).
Signal Type: Isolated Digital Input/Output, Precision Analog Control Signal; Analog Input Range: ±10V DC, 4~20mA DC (Configurable); Digital I/O Count: 16 Digital Inputs, 10 Digital Outputs (Software Configurable for Function).
2.3 Protection Functions
Over-Voltage Protection (OVP): 30V DC (Power Terminal, Auto-Recovery Mode); Over-Current Protection (OCP): 2.0A DC (Power Loop, Latch Mode, Manual Reset).
ESD Protection: ±12kV (Contact), ±18kV (Air, Per IEC 61000-4-2); Surge Protection: ±2.5kV (Line to Ground, Per IEC 61000-4-5); Over-Temperature Protection: Triggered at 85℃ (Auto-Shutdown, Alarm Output).
3. Environmental Specifications
3.1 Operating Environment
Operating Temperature: -20℃~65℃ (No Derating); Storage Temperature: -40℃~85℃ (No Condensation).
Relative Humidity: 5%~95% RH (Non-Condensing, -20℃~65℃); Altitude: ≤2500m (Above Sea Level, Normal Operation); Above 2500m, derate 1.5% per 100m.
Vibration Resistance: 10Hz~500Hz, 0.8G (X/Y/Z Directions, Continuous Operation, Per IEC 60068-2-6); Shock Resistance: 20G (11ms Duration, Half-Sine Wave, Per IEC 60068-2-27).
3.2 EMC Standards
Emission Standards: EN 55011 Class A, EN 61800-3; Immunity Standards: EN 61000-4-3 (Radiated Immunity 10V/m), EN 61000-4-4 (EFT ±4kV Power Line, ±2kV Signal Line).
Protection Degree: IP20 (Board-Level); Pollution Degree: 2; Over-Voltage Category: Ⅱ (Industrial Environment).