1 PCS used Fluke FLK-PMM-7000K Pressure Measurement Module #LYQ007
1 PCS used Fluke FLK-PMM-7000K Pressure Measurement Module #LYQ007
|
Parameter Category
|
Parameter Name
|
FLK-PMM-7000K Specification
|
|
Basic Information
|
Product Model
|
FLK-PMM-7000K; Fluke Genuine Original Pressure Measurement Module, 100% unused and unrefurbished genuine parts
|
|
Manufacturer Standard
|
Manufactured by Fluke; Compliant with ISO 9001, ISO 17025, CE, RoHS, FCC Standards; Conforms to Fluke Internal Technical and Measurement Norms
|
|
|
Product Application
|
Industrial Automation, Precision Pressure Testing, Aerospace Component Testing, Automotive Manufacturing, Scientific Research Experiments, Pressure Monitoring Systems
|
|
|
Core Pressure Measurement Parameters
|
Measurement Range
|
0~7000 psi (0~48.26 MPa); Optional Extended Range: -14.7~7000 psi (-0.101~48.26 MPa); Wide Measurement Range, Adapt to Different Pressure Scenarios
|
|
Measurement Accuracy
|
≤±0.05% FS (Full Scale); ≤±0.02% FS (Calibrated Range); High Measurement Precision, Ensure Accurate Data Acquisition
|
|
|
Resolution
|
0.01 psi (0.000069 MPa); High Resolution, Effectively Capture Small Pressure Changes, Suitable for Precision Measurement
|
|
|
Non-Linearity
|
≤±0.03% FS; Low Non-Linearity, Ensure Consistent Measurement Accuracy Throughout the Entire Measurement Range
|
|
|
Hysteresis
|
≤±0.02% FS; Small Hysteresis Error, Ensure Stable Measurement Results During Pressure Rise and Fall
|
|
|
Repeatability
|
≤±0.01% FS; Excellent Repeatability, Ensure Consistent Measurement Results Under the Same Pressure Conditions
|
|
|
Precision & Signal Parameters
|
Response Time
|
≤1ms (Typical); ≤5ms (Max); Fast Response Speed, Rapid Capture Pressure Changes, Suitable for Dynamic Pressure Measurement
|
|
Sampling Rate
|
100 Hz ~ 10 kHz (Adjustable); Flexible Sampling Rate, Adapt to Static and Dynamic Pressure Measurement Requirements
|
|
|
Output Signal
|
Analog Output: 4~20 mA, 0~5 V, 0~10 V (Selectable); Digital Output: RS485, Modbus RTU; Dual Signal Output, Convenient for Data Transmission and Integration
|
|
|
Signal Noise
|
≤0.005% FS (RMS); Low Signal Noise, Ensure Stable and Reliable Measurement Data, Reduce Interference Impact
|
|
|
Temperature Coefficient
|
≤50 ppm/°C (0~50°C); ≤100 ppm/°C (-40~85°C); Small Temperature Drift, Ensure Measurement Accuracy Under Different Temperature Conditions
|
|
|
Zero Drift
|
≤±0.01% FS/Year (Room Temperature); Low Zero Drift, Reduce Calibration Frequency, Improve Operational Efficiency
|
|
|
Protection & Safety Parameters
|
Overpressure Protection
|
150% of Rated Full Scale; Automatic Protection When Pressure Exceeds Threshold, Prevent Module Damage, Alarm Signal Output Synchronously
|
|
Overload Protection
|
120% of Rated Full Scale; Constant Current Limiting Protection, Avoid Overload Damage to Internal Sensing and Circuit Components
|
|
|
Signal Loss Alarm
|
Digital Alarm Signal Output (TTL Level); Alarm Prompt When Signal Transmission Interrupts, Facilitate Timely Troubleshooting
|
|
|
ESD Protection
|
±8kV (Contact), ±15kV (Air); Effectively Protect the Module from Static Damage, Ensure Stable Operation in Electronic Manufacturing and Testing Environments
|
|
|
Pressure Media Compatibility
|
Compatible with Oil, Gas, Water, Hydraulic Fluid and Other Non-Corrosive Media; Optional Corrosion-Resistant Version for Corrosive Media Scenarios
|
|
|
Environmental & Structural Parameters
|
Operating Temperature
|
-40°C ~ 85°C, Wide Temperature Range, Adapting to Various Industrial Harsh Environments and Extreme Temperature Scenarios
|
|
Storage Temperature
|
-55°C ~ 100°C, Stable Storage Performance, No Performance Degradation After Long-Term Storage in Warehouse or Transportation
|
|
|
Relative Humidity
|
5% ~ 95% (Non-Condensing), Resisting Humid Industrial and Testing Environments, No Short Circuit or Measurement Error Risk
|
|
|
Structure Material
|
Industrial-Grade Stainless Steel (Sensing Part) + Aluminum Alloy Shell (Circuit Part); Anti-Corrosion, Anti-Oxidation, High Mechanical Strength, Dust-Proof and Waterproof Design (IP65)
|
|
|
Interface & Compatibility Parameters
|
Pressure Interface
|
1/4 NPT (Male); Optional: BSPP, BSPT; High-Strength Sealing Design, Ensure No Pressure Leakage, Suitable for Industrial Pipeline Connection
|
|
Electrical Interface
|
M12 Connector (5-Pin); Anti-Loose, Waterproof Design (IP65); Convenient for Wiring and Disassembly, Suitable for Industrial Field Installation
|
|
|
System Compatibility
|
Compatible with Fluke Data Acquisition Systems, Industrial PLCs, SCADA Systems; Support Modbus RTU Communication Protocol, Easy for System Integration and Centralized Monitoring
|
1 .Our company specializes in automation industrial control accessories. We have more than 100,000 products.
Including : frequency converter, servo driver, servo motor, data acquisition card, industrial camera, touch screen, circuit board, DCS module, soft starter, industrial computer,encoder... etc
2,We accept PayPal transaction. All products provided 60 days warranty. We can send the goods by fast express to all over world.
3. We can supply the product in brand new or used condition to meet your requirement.The picture and price show on our store is not real, before purchasing, please contact us to provide you with accurate quotation and real pictures.
4. If you can not find the product you need in our store, please contact us .we will check it for you.