1 PCS new HORIBA Resistivity Sensor ERD-001L-T-Y10M #LYQ007
1 PCS new HORIBA Resistivity Sensor ERD-001L-T-Y10M #LYQ007
|
Parameter Category
|
Parameter Name
|
ERD-001L-T-Y10M Specification
|
|
Basic Information
|
Product Model
|
ERD-001L-T-Y10M; HORIBA Genuine Original Resistivity Sensor, 100% unused and unrefurbished genuine parts; Industrial-grade high-precision resistivity detection sensor
|
|
Manufacturer Standard
|
Manufactured by HORIBA; Complies with CE, UL, IEC 61010-1, IEC 61326-1, EN 55032 (Class B), RoHS 2.0 Standards; Conforms to HORIBA Internal Technical and Quality Norms for Resistivity Sensors; Anti-EMI/EMS design meets industrial high-precision detection requirements
|
|
|
Product Application
|
Water Treatment (Pure Water, Wastewater), Chemical Industry (Chemical Solution Detection), Semiconductor Manufacturing (High-Purity Liquid Detection), Pharmaceutical Industry (Pharmaceutical Solution Detection), Food and Beverage Industry (Beverage, Food Processing Liquid Detection), Laboratory Precision Detection, Intelligent Production Lines requiring high-precision resistivity measurement
|
|
|
Measurement Core Parameters
|
Measurement Range
|
Resistivity: 1 Ω·cm ~ 10¹² Ω·cm; Conductivity (Derivable): 10⁻¹² S/cm ~ 1 S/cm; Wide measurement range, adapting to various detection scenarios from low resistivity to high resistivity
|
|
Measurement Precision
|
±0.1% FS (Full Scale) at 25℃; ±0.5% FS (Full Scale) in the entire operating temperature range; High measurement precision, meeting industrial high-precision detection requirements
|
|
|
Repeatability
|
≤±0.05% FS; Stable repeatability, ensuring consistent measurement results in mass detection or long-term continuous detection
|
|
|
Temperature Compensation Range
|
0℃ ~ 100℃; Automatic temperature compensation, compensation accuracy: ±0.1% / ℃; Effectively eliminate the influence of temperature on resistivity measurement results
|
|
|
Reference Temperature
|
25℃ (Default); Support manual setting of reference temperature (0℃ ~ 100℃); Convenient for matching different detection standards and requirements
|
|
|
Response Time
|
≤100 ms (90% Response); Fast response speed, adapting to high-speed continuous detection scenarios and real-time data collection requirements
|
|
|
Measurement Principle
|
Four-Electrode Method; Effectively avoid polarization effect and contact resistance interference, ensure measurement accuracy especially in high-resistivity and low-conductivity media
|
|
|
Input & Output Parameters
|
Output Signal Type
|
Dual Output: 4~20 mA DC (Isolated, Load Resistance ≤500 Ω) + RS485 (Modbus-RTU Protocol); Support simultaneous output of resistivity and temperature data, convenient for data transmission and integration
|
|
Output Resolution
|
Resistivity: 0.001 Ω·cm (Low Range) ~ 1 Ω·cm (High Range); Temperature: 0.1℃; High resolution, ensuring fine data collection and analysis
|
|
|
Power Supply Voltage
|
24 V DC (±10% Fluctuation); Optional 12 V DC Input (Customizable); Stable power supply, ensuring high-precision measurement and long-term stable operation
|
|
|
Rated Power Consumption
|
≤15 W (Full Load); Low power consumption, energy-saving and environmentally friendly, reducing heat generation and equipment operation cost
|
|
|
Communication Baud Rate
|
RS485: 9600~115200 bps (Adjustable); Support remote parameter configuration and data query, convenient for centralized control and management
|
|
|
Interface Protection
|
2500 V AC Optical Isolation (1 Minute); ESD Protection ±15 kV (Contact), ±25 kV (Air); Protect internal components from signal interference and damage
|
|
|
Protection & Safety Parameters
|
Over-Temperature Protection
|
Built-in High-Precision Temperature Sensor; Alarm & Cut off Output when Internal Temperature ≥70℃; Automatic Recovery after Cooling to ≤60℃; Prevent sensor damage due to overheating
|
|
Over-Voltage Protection
|
Power Supply Over-Voltage Protection: ≥30 V DC; Automatically cut off power when abnormal, protecting the sensor and connected equipment
|
|
|
Short-Circuit Protection
|
Output Short-Circuit Protection; Automatically cut off output when short circuit occurs, avoid damage to internal circuit and connected instruments
|
|
|
ESD Protection
|
±15 kV (Contact), ±25 kV (Air); Complies with IEC 61000-4-2; Protects internal measurement chip and electronic components from static damage
|
|
|
EMI/EMS Protection
|
Complies with IEC 61000-4-3 (Radiated Immunity, 10 V/m), IEC 61000-4-4 (Electrical Fast Transient, 2 kV); Strong anti-electromagnetic interference ability, adapt to complex industrial electromagnetic environment
|
|
|
Fault Alarm Function
|
Built-in Fault Self-Diagnosis Function; Output Alarm Signal when Sensor Fault, Power Supply Abnormality or Measurement Overrange; Support Fault Log Storage (Max 500 Entries); Convenient for fault diagnosis and maintenance
|
|
|
Password Protection
|
Support 6~16 Bit Password Protection; Prevent misoperation and parameter modification; Protect measurement precision parameters and sensor settings
|
|
|
Environmental & Structural Parameters
|
Operating Temperature
|
-5℃ ~ 85℃; 1% Derating per °C over 70℃; Stable operation in extreme temperature environments, adapt to various industrial working conditions
|
|
Storage Temperature
|
-20℃ ~ 90℃; Stable storage performance, no performance degradation after long-term storage in harsh environments
|
|
|
Relative Humidity
|
5% ~ 95% (Non-Condensing); Resists humid industrial environments, no short circuit or malfunction, ensure long-term stable operation
|
|
|
Protection Class
|
IP65 (Probe); IP54 (Transmitter); Dustproof and waterproof design, suitable for installation in outdoor or wet industrial sites
|
|
|
Structure Material
|
Probe: Titanium Alloy + PTFE; Transmitter: Industrial-Grade FR-4 Circuit Board + Aluminum Alloy Shell; Corrosion-resistant, anti-oxidation, high mechanical strength; Adapt to corrosive detection media
|
|
|
Installation Type
|
Immersion Type / Pipeline Type (Optional); Installation Thread: G1/2 (Standard), Customizable; Easy to install and disassemble, convenient for maintenance and calibration
|
|
|
Functional & Other Parameters
|
Start-up Time
|
≤500 ms (24 V DC, No Load); Fast start-up, quickly enter working state, realize real-time detection
|
|
Remote Control Function
|
Support Remote On/Off, Parameter Configuration, Data Query via RS485/Ethernet (Optional); Convenient for centralized control of intelligent production lines and detection systems
|
|
|
Parameter Storage
|
Built-in EEPROM; Support 8 Groups of Measurement Parameters Storage & Call; Convenient for switching between different detection media and scenarios
|
|
|
Calibration Function
|
Support Manual Calibration & Automatic Calibration; Provide HORIBA Original Calibration Solution (Optional); Ensure long-term measurement precision and parameter consistency
|
1 .Our company specializes in automation industrial control accessories. We have more than 100,000 products.
Including : frequency converter, servo driver, servo motor, data acquisition card, industrial camera, touch screen, circuit board, DCS module, soft starter, industrial computer,encoder... etc
2,We accept PayPal transaction. All products provided 60 days warranty. We can send the goods by fast express to all over world.
3. We can supply the product in brand new or used condition to meet your requirement.The picture and price show on our store is not real, before purchasing, please contact us to provide you with accurate quotation and real pictures.
4. If you can not find the product you need in our store, please contact us .we will check it for you.