1 PCS used ASM Temperature Controller 02-E10155/D #LYQ007
1 PCS used ASM Temperature Controller 02-E10155/D #LYQ007
| Parameter Category | Parameter Name | Specification |
|---|---|---|
| Basic Identification | Model Number | 02-E10155/D |
| Basic Identification | Product Type | ASM OEM In-Panel Temperature Controller (Industrial Grade) |
| Basic Identification | Mounting Form | DIN Rail / Panel Mount (Dual Compatibility) |
| Basic Identification | Enclosure Rating | IP65 (Front Panel); IP20 (Rear Terminals) |
| Input Specifications | Sensor Input Type | Pt100 / JPt100 (3-Wire, 4-Wire Configurable); Thermocouple K/J/T/E (Optional) |
| Input Specifications | Analog Input | 4–20 mA, 0–10 V (Scalable for Process Signals) |
| Input Specifications | Input Impedance | ≥1 MΩ (Voltage); ≤100 Ω (Current); ≥10 kΩ (RTD) |
| Input Specifications | Cold-Junction Compensation | Built-in, ±0.5°C Accuracy (-10°C to +60°C) |
| Temperature Range | Measuring Range (RTD) | -200°C to +600°C |
| Temperature Range | Measuring Range (Thermocouple K) | -50°C to +1250°C |
| Temperature Range | Setpoint Range | Same as Measuring Range |
| Accuracy & Resolution | Basic Accuracy (RTD) | ±0.1% of Reading + 0.2°C (25°C Reference) |
| Accuracy & Resolution | Basic Accuracy (Thermocouple) | ±0.2% of Reading + 0.5°C |
| Accuracy & Resolution | Display Resolution | 0.1°C (Full Scale) |
| Accuracy & Resolution | Control Resolution | 0.01°C (PID Algorithm) |
| Control Performance | Control Mode | 2-Degree PID (Auto-Tuning); On/Off (Selectable) |
| Control Performance | Control Cycle | 0.1 s, 0.2 s, 0.5 s, 1–99 s (User Configurable) |
| Control Performance | Response Time | ≤ 200 ms (Step Change, 10% of Range) |
| Control Performance | Overshoot | ≤ 2% (Typical, Auto-Tuned) |
| Output Specifications | Control Output 1 | SSR Drive: 5 V DC, ≤ 100 mA (Sink/Source) |
| Output Specifications | Control Output 2 | Relay: SPST-NO, 250 V AC / 3 A (Resistive Load) |
| Output Specifications | Alarm Outputs | 2 × SPST-NO Relays (Configurable: High/Low Temp, Deviation, Sensor Fault) |
| Output Specifications | Output Isolation | 3 kV AC (1 min) Between Input/Output/Power |
| Power Supply | Rated Voltage | 100–240 V AC (50/60 Hz); 24 V DC ±10% (Optional) |
| Power Supply | Voltage Tolerance | -15% to +10% of Rated |
| Power Supply | Power Consumption | ≤ 8 VA (AC); ≤ 5 W (DC) |
| Communication | Interface | RS-485 (Modbus-RTU) |
| Communication | Baud Rate | 9.6 kbps to 115.2 kbps (Auto-Detect) |
| Communication | Nodes | Up to 32 Devices per Bus |
| Display & Indicators | Display Type | 4-Digit 7-Segment LED (PV: Red, SV: Green) |
| Display & Indicators | Status LEDs | Power (Green), Run (Blue), Alarm (Red), Fault (Amber) |
| Mechanical Parameters | Dimensions (W×H×D) | 48 mm × 48 mm × 110 mm (DIN 48×48) |
| Mechanical Parameters | Net Weight | ≈ 0.18 kg |
| Mechanical Parameters | Terminal Type | Screw Terminals (0.5–2.5 mm² Wire) |
| Mechanical Parameters | Enclosure Material | Front: PC (UL94 V-0); Rear: ABS (UL94 V-0) |
| Environmental Ratings | Operating Temperature | -10°C to +55°C (Non-Condensing) |
| Environmental Ratings | Storage Temperature | -40°C to +85°C |
| Environmental Ratings | Operating Humidity | 10%–90% RH (Non-Condensing) |
| Environmental Ratings | Vibration Resistance | 10–55 Hz, 2 g (3 Axes, 10 min Each) – No Malfunction |
| Environmental Ratings | Shock Resistance | 50 g (11 ms, Half-Sine) – No Damage |
| Safety & EMC | Safety Standards | IEC 61010-1, UL 61010C-1, CSA C22.2 No. 1010-1 |
| Safety & EMC | EMC Standards | EN 61326-1 (EMI: EN 55011 Class A; EMS: EN 61000-4-2/3/4/5) |
| Safety & EMC | Insulation Resistance | ≥ 100 MΩ (500 V DC, Between Live Parts & Ground) |
| Safety & EMC | Dielectric Strength | 2 kV AC (1 min, Between Input/Output; 3 kV AC Between Power & All) |
| Reliability | MTBF | ≥ 100,000 Hours (25°C, Rated Voltage) |
| Reliability | Relay Life | 100,000 Operations (Full Load); 10,000,000 Operations (10% Load) |
| Calibration | Factory Calibration | 100% Calibrated with NIST-Traceable Standards |
| Calibration | Recommended Calibration Interval | 12 Months (Industrial Use) |
| Special Features | Self-Diagnosis | Sensor Open/Short, Power Failure, Heater Breakage (SSR Drive) |
| Special Features | Power Failure Memory | Non-Volatile EEPROM (10-Year Data Retention) |
| Special Features | Password Protection | 4-Digit PIN (Configurable Access Levels) |
1 .Our company specializes in automation industrial control accessories. We have more than 100,000 products.
Including : frequency converter, servo driver, servo motor, data acquisition card, industrial camera, touch screen, circuit board, DCS module, soft starter, industrial computer,encoder... etc
2,We accept PayPal transaction. All products provided 60 days warranty. We can send the goods by fast express to all over world.
3. We can supply the product in brand new or used condition to meet your requirement.The picture and price show on our store is not real, before purchasing, please contact us to provide you with accurate quotation and real pictures.
4. If you can not find the product you need in our store, please contact us .we will check it for you.


