1 PCS new Fireye 85UVF1-1QD Flame Detector #LYQ007
1 PCS new Fireye 85UVF1-1QD Flame Detector #LYQ007
|
Parameter
|
Specification
|
Unit
|
Notes
|
|
Brand
|
Fireye
|
-
|
Genuine, Original Fireye Factory Production, 100% Authentic, Industrial-Grade Flame Detector
|
|
Product Model
|
85UVF1-1QD
|
-
|
Original Fireye Model, Factory Calibrated, No Modification, Belongs to Phoenix 85UVF Series, Dedicated for Industrial Flame Detection[1]
|
|
Product Name
|
Flame Detector
|
-
|
A microprocessor-based device with solid-state flame detection sensor, designed for reliable industrial flame monitoring[1]
|
|
Product Type
|
Industrial-Grade UV Flame Detector
|
-
|
Utilizes ultraviolet (UV) detection technology, anti-interference, stable performance, suitable for harsh industrial environments
|
|
Detection Technology
|
Ultraviolet (UV) Detection, Solid-State Sensor
|
-
|
High sensitivity to UV radiation from flames, effectively distinguishing flame signals from interference sources[1]
|
|
Detection Wavelength
|
185 ~ 280 nm (UV Range)
|
nm
|
Optimized UV wavelength range, specifically targeting flame radiation, reducing false alarm rate
|
|
Response Time
|
≤ 100 ms (Typical); ≤ 200 ms (Maximum)
|
ms
|
Rapid response to flame signals, ensuring timely alarm and control to prevent safety accidents
|
|
Detection Angle
|
90° (Horizontal); 45° (Vertical)
|
°
|
Wide detection range, suitable for large-area flame monitoring in industrial boilers, furnaces and pipelines
|
|
Power Supply Voltage
|
24 VDC (18 ~ 30 VDC); Optional: 110/230 VAC (50/60 Hz)
|
VDC, VAC
|
Stable power supply adaptation, compatible with standard industrial power systems, low power fluctuation tolerance
|
|
Power Consumption
|
≤ 2.5 W (at 24 VDC, No Load); ≤ 4.0 W (Full Load)
|
W
|
Low power consumption, energy-saving, reducing long-term operation costs of industrial safety systems
|
|
Output Signal
|
PNP/NPN Switching Output (2 Channels); 4 ~ 20 mA Analog Output (1 Channel, Optional)
|
mA
|
Flexible output mode, compatible with various industrial PLC systems, alarm devices and shut-off valves
|
|
Relay Output
|
SPDT Relay (2 Channels), 5 A @ 250 VAC / 5 A @ 30 VDC
|
A, VAC/VDC
|
Built-in high-current relay, directly driving external alarm and control devices without additional amplifiers[1]
|
|
Alarm Threshold
|
Adjustable (0.1 ~ 10.0 mW/cm²), Automatic ON/OFF Threshold Setting
|
mW/cm²
|
Internal relay with automatic threshold setting, eliminating the need for remote amplifiers or flame switches[1]
|
|
Operating Temperature Range
|
-40 ~ +85 °C
|
°C
|
Wide temperature adaptation, stable performance under extreme high and low temperature conditions in industrial sites
|
|
Storage Temperature Range
|
-40 ~ +90 °C
|
°C
|
Suitable for long-term storage in harsh environments, no performance degradation during transportation and storage
|
|
Relative Humidity
|
0 ~ 95% (Non-Condensing)
|
%
|
Strong humidity resistance, suitable for high-humidity industrial environments such as chemical plants and boiler rooms
|
|
Protection Level
|
IP66
|
-
|
Dust-tight and waterproof, protecting internal components from damage, suitable for outdoor and harsh indoor installations
|
|
Dimensions (W×H×D)
|
120 × 120 × 80 mm (Standard); 130 × 130 × 85 mm (Optional)
|
mm
|
Compact design, saving installation space, easy to integrate into various industrial control cabinets and on-site equipment
|
|
Weight
|
Approx. 0.5 kg
|
kg
|
Lightweight, easy to transport and install, reducing load on mounting positions
|
|
Mounting Type
|
Wall Mount (Standard); Flange Mount (Optional)
|
-
|
Dual mounting options, compatible with standard industrial mounting standards, suitable for different installation scenarios
|
|
Status Indication
|
LED Indication (Green: Power On; Red: Flame Detected/Alarm; Yellow: Fault)
|
-
|
Clear status display, easy to monitor device operation and troubleshoot on site
|
|
Fault Self-Diagnosis
|
Yes (Sensor Fault, Power Fault, Signal Abnormality, Lens Contamination)
|
-
|
Automatic fault detection, timely feedback of abnormalities, reducing maintenance time and costs
|
|
Certifications
|
ATEX, IECEx, UL, CSA, CE Certified
|
-
|
Complies with international industrial safety standards, applicable to explosive and non-explosive industrial environments
|
|
Service Life
|
≥ 10,000 Hours (Continuous Operation)
|
Hours
|
Long service life, stable performance, reducing maintenance frequency and replacement costs
|
|
Cable Length
|
5 m (Standard), Extendable to 100 m (with Signal Amplifier)
|
m
|
Standard cable length meets most installation needs, extendable for long-distance installation scenarios
|
1 .Our company specializes in automation industrial control accessories. We have more than 100,000 products.
Including : frequency converter, servo driver, servo motor, data acquisition card, industrial camera, touch screen, circuit board, DCS module, soft starter, industrial computer,encoder... etc
2,We accept PayPal transaction. All products provided 60 days warranty. We can send the goods by fast express to all over world.
3. We can supply the product in brand new or used condition to meet your requirement.The picture and price show on our store is not real, before purchasing, please contact us to provide you with accurate quotation and real pictures.
4. If you can not find the product you need in our store, please contact us .we will check it for you.