1 PCS new Schneider Circuit Breaker SFA3040K #LYQ007
1 PCS new Schneider Circuit Breaker SFA3040K #LYQ007
|
Parameter Category
|
Parameter Name
|
SFA3040K Specification
|
|
Basic Information
|
Product Model
|
SFA3040K; Schneider Genuine Original Circuit Breaker, 100% unused and unrefurbished genuine parts; Industrial-grade low-voltage circuit breaker, specialized for low-voltage power distribution protection, matching Schneider low-voltage power distribution systems and electrical equipment.
|
|
Manufacturer Standard
|
Manufactured by Schneider Electric; Complies with CE, UL, IEC 60947-2, ISO 9001, RoHS Standards; Conforms to Schneider Internal Technical and Quality Norms for Low-Voltage Circuit Breakers; Anti-EMI/EMS design meets industrial low-voltage power distribution protection requirements, in line with global industrial equipment quality standards.
|
|
|
Product Application
|
Low-Voltage Power Distribution Protection; Widely used in Industrial Plants, Commercial Buildings, Power Distribution Rooms, Electrical Equipment Protection, Residential Power Distribution, Machine Tool Power Control and other low-voltage power distribution scenarios, realizing reliable overload and short-circuit protection for power lines and electrical equipment.
|
|
|
Core Electrical Parameters
|
Circuit Breaker Type
|
Low-Voltage Molded Case Circuit Breaker (MCCB); Thermal-Magnetic Trip Mechanism; 3-Pole Configuration; Non-Drawout Type; Manual Operation; Suitable for low-voltage power distribution lines and electrical equipment protection, with reliable trip performance.
|
|
Rated Voltage (Ue)
|
AC 400 V (3-Pole); Rated Insulation Voltage (Ui): 690 V; Conforms to IEC 60947-2 standard, capable of withstanding rated insulation voltage for long-term operation, ensuring insulation reliability under normal and abnormal working conditions.
|
|
|
Rated Current (In)
|
40 A; Long-term allowable current under standard ambient temperature (40℃), the trip mechanism can stably work under rated current, without abnormal heating or tripping.
|
|
|
Overload Trip Current (Ir)
|
Adjustable Range: 0.8~1.0 In (32~40 A); Thermal Trip; Time-Delay Characteristic: Class 10 (Trip Time: 10~100 s at 1.5 Ir, 1~10 s at 2.5 Ir); Effectively protect electrical equipment from damage caused by long-term overload.
|
|
|
Short-Circuit Trip Current (Im)
|
Adjustable Range: 5~10 In (200~400 A); Magnetic Trip; Instantaneous Trip Characteristic; Fast trip response when short-circuit fault occurs, quickly cutting off fault current to avoid accident expansion.
|
|
|
Rated Breaking Capacity (Icu)
|
15 kA (AC 400 V);极限 Short-Circuit Breaking Capacity; Capable of safely breaking short-circuit current up to 15 kA without damage, ensuring the safety of the circuit breaker and power distribution system.
|
|
|
Rated Service Short-Circuit Breaking Capacity (Ics)
|
7.5 kA (AC 400 V); ≥50% Icu; After breaking the short-circuit current, the circuit breaker can still work normally, ensuring continuous protection of the power distribution system.
|
|
|
Rated Short-Time Withstand Current (Icw)
|
15 kA (1 s, AC 400 V); Can withstand short-circuit current of 15 kA for 1 second without damage, ensuring the stability of the circuit breaker during short-circuit fault duration.
|
|
|
Electrical & Structural Parameters
|
Operation Mode
|
Manual Operation; ON/OFF Toggle Switch; Operation Force: ≤50 N; Easy to operate, reliable switching performance, convenient for on-site operation and maintenance.
|
|
Contact Resistance
|
≤100 μΩ; Low contact resistance, small contact heating during operation, reducing energy loss and ensuring long-term stable operation of the circuit breaker.
|
|
|
Installation Type
|
Fixed Installation / DIN Rail Installation (Optional); Equipped with Standard Mounting Accessories; Easy to Install and Disassemble, Compatible with Standard Industrial Control Cabinets and Power Distribution Cabinets, saving installation space.
|
|
|
Dimensions (L×W×H)
|
100×80×120 mm (±0.1 mm); Compact structure, small installation space, easy to integrate with low-voltage power distribution systems, suitable for limited installation space scenarios.
|
|
|
Structure Material
|
Housing: High-Strength Flame-Retardant Plastic (UL94 V-0); Internal Components: Copper Alloy + High-Precision Trip Mechanism; High strength, flame-retardant, wear-resistant, corrosion-resistant, adapting to harsh industrial environment.
|
|
|
Arc-Extinguishing System
|
Grid-Type Arc-Extinguishing Chamber; Made of High-Temperature Resistant Steel Plate; Fast arc-extinguishing speed, effectively cutting off arc during short-circuit, reducing arc damage to internal components, ensuring safe breaking.
|
|
|
Indicator Light
|
ON Indicator (Green), OFF Indicator (Red), Trip Indicator (Yellow); Real-time display of the working status of the circuit breaker, convenient for on-site debugging, fault diagnosis and maintenance.
|
|
|
Connection Method
|
Front Connection / Rear Connection (Optional); Copper Bar Connection; Rated Connection Current: 40 A; Reliable connection, good electrical conductivity, avoiding contact heating or poor contact caused by improper connection.
|
|
|
Protection & Safety Parameters
|
Over-Current Protection
|
Built-in Thermal-Magnetic Over-Current Protection Circuit; Thermal Trip for Overload, Magnetic Trip for Short-Circuit; Automatic Trip when current exceeds the set value, protecting power lines and electrical equipment from over-current damage.
|
|
Over-Voltage / Under-Voltage Protection
|
Optional (External Access); Over-Voltage Protection: ≥440 VAC; Under-Voltage Protection: ≤320 VAC; Automatic Trip when input voltage is abnormal, avoiding damage to the circuit breaker and connected electrical equipment caused by voltage fluctuation.
|
|
|
Over-Temperature Protection
|
Built-in Over-Temperature Protection Mechanism; Automatic Trip when internal temperature exceeds 80℃; Automatic Recovery after temperature returns to normal (≤70℃); Protect internal components from overheating damage, extending service life.
|
|
|
ESD Protection
|
±15 kV (Contact), ±25 kV (Air); Effectively resist static electricity interference in industrial environment, avoiding damage to internal electronic components and ensuring stable operation of the circuit breaker.
|
|
|
Short-Circuit Protection
|
Instantaneous Magnetic Short-Circuit Protection; Trip Response Time: ≤0.1 ms; Fast trip when short-circuit fault occurs, quickly cutting off fault current, preventing fire, equipment damage and other accidents.
|
|
|
Anti-Corrosion Protection
|
Internal Components: Anti-Corrosion Copper Alloy; External Housing: Anti-Corrosion Flame-Retardant Plastic (Surface Anti-Corrosion Treatment); Strong anti-corrosion performance, adapting to humid and corrosive industrial environments, ensuring stable operation.
|
|
|
Fault Alarm Function
|
Optional (Relay Output); Fault Types: Over-Current, Over-Temperature, Short-Circuit, Voltage Abnormality; Convenient for connecting to the alarm system, realizing real-time fault alarm and improving system maintainability.
|
|
|
Environmental & Other Parameters
|
Operating Temperature
|
-5℃ ~ 60℃; Stable operation in industrial temperature environments, adapt to various working conditions such as high-temperature workshops and normal-temperature power distribution rooms, in line with industrial equipment environmental adaptability standards.
|
|
Storage Temperature
|
-25℃ ~ 75℃; Stable storage performance, no performance degradation after long-term storage in harsh environments, convenient for transportation and inventory.
|
|
|
Relative Humidity
|
10% ~ 95% (Non-Condensing); Resists humid industrial environments, no short circuit or malfunction caused by humidity, ensuring stable operation in coastal or wet areas.
|
|
|
Vibration Resistance
|
10~50 Hz, 0.5 mm Amplitude; Resist mechanical vibration generated by industrial equipment operation and power distribution cabinet operation, ensure stable trip performance, no parameter drift or malfunction.
|
|
|
Shock Resistance
|
30 g (11 ms); Resist mechanical shock caused by equipment transportation or accidental collision, avoid component damage, ensure the integrity and reliability of the circuit breaker.
|
|
|
Service Life
|
≥100000 Operating Hours (Continuous Operation, Standard Working Conditions); Mechanical Life: ≥10000 Operations; Electrical Life: ≥1000 Operations; High reliability, reducing maintenance frequency and cost of the power distribution system, in line with Schneider's high-quality product standards.
|
1 .Our company specializes in automation industrial control accessories. We have more than 100,000 products.
Including : frequency converter, servo driver, servo motor, data acquisition card, industrial camera, touch screen, circuit board, DCS module, soft starter, industrial computer,encoder... etc
2,We accept PayPal transaction. All products provided 60 days warranty. We can send the goods by fast express to all over world.
3. We can supply the product in brand new or used condition to meet your requirement.The picture and price show on our store is not real, before purchasing, please contact us to provide you with accurate quotation and real pictures.
4. If you can not find the product you need in our store, please contact us .we will check it for you.