1 PCS used MEIDEN Control Board MSC-04-01 #LYQ007
1 PCS used MEIDEN Control Board MSC-04-01 #LYQ007
|
Parameter Category
|
Parameter Name
|
Original Factory Precision Specification
|
|
Basic Information
|
Product Model
|
MSC-04-01; MEIDEN Genuine Original Industrial Control Board, 100% unused and unrefurbished genuine parts, consistent with MEIDEN's official model coding standards. It belongs to high-precision industrial-grade control equipment, designed for dedicated matching with various industrial automation control systems, with fixed configuration and excellent environmental adaptability, focusing on high-precision signal processing, stable logic control and reliable fault feedback.
|
|
Manufacturer Standard
|
Manufactured by MEIDEN (Genuine Original Factory); Compliant with ISO 9001 Quality Certification, CE, RoHS, UL, IEC 61131-2, EN 55011 Industrial Standards; Conforms to MEIDEN Internal Technical Standard and Control Board Manufacturing Norms, as well as Low Voltage Directive (73/23/EEC) and EMC Directive (89/336/EEC), meeting the precision calibration requirements of international industrial control equipment standards and related industrial control specifications.
|
|
|
Core Electrical & Control Parameters
|
Board Type
|
High-Precision Industrial Control Board; Digital-Analog Hybrid Control; Built-in 32-bit High-Speed Microcontroller; Support Real-Time Logic Control and Signal Processing; Integrated Signal Acquisition, Control Output and Fault Diagnosis Modules, reducing external circuit configuration and improving integration.
|
|
Power Supply Parameters
|
Input Voltage: 24V DC ±10%; Rated Input Current: 1.5A; Maximum Input Current: 2.5A; Power Consumption: ≤36W (Under Rated Working Conditions); Built-in Power Filter and Voltage Stabilization Module, ensuring stable power supply under voltage fluctuation, effectively preventing power supply interference from affecting control accuracy.
|
|
|
Analog Input Parameters
|
Input Channels: 8 Channels (Configurable); Input Type: 4~20mA DC / 0~10V DC (Dual Optional); Resolution: 12 Bits; Accuracy: ±0.1% FS; Sampling Frequency: 100Hz; Input Impedance: ≥1MΩ (Voltage Input), ≤100Ω (Current Input); Suitable for various sensor signal acquisition such as temperature, pressure and flow.
|
|
|
Digital Input Parameters
|
Input Channels: 16 Channels; Input Type: Optically Isolated Dry Contact / NPN Open Collector; Input Voltage: 24V DC ±10%; Response Time: ≤1ms; Input Current: 5~10mA; Anti-Interference Voltage: ≥2500V AC (Isolation), effectively resisting industrial electromagnetic interference.
|
|
|
Analog Output Parameters
|
Output Channels: 4 Channels; Output Type: 4~20mA DC / 0~10V DC (Dual Optional); Resolution: 12 Bits; Accuracy: ±0.2% FS; Load Capacity: ≤500Ω (Current Output), ≥10kΩ (Voltage Output); Stable output signal, suitable for controlling executive components such as frequency converters and regulators.
|
|
|
Digital Output Parameters
|
Output Channels: 8 Channels; Output Type: NPN Transistor / Relay (Dual Optional); Transistor Output: 24V DC, ≤1A (Per Channel); Relay Output: 250V AC / 30V DC, ≤5A (Per Channel); Short-Circuit Protected, ensuring safe and stable operation of the board.
|
|
|
Control Response Time
|
Logic Control Response Time: ≤5ms; Signal Processing Response Time: ≤3ms; Output Delay Time: ≤1ms; Fast response speed, adapting to high-precision real-time control scenarios, ensuring accurate and timely control of industrial equipment.
|
|
|
Storage & Clock Parameters
|
Built-In EEPROM: ≥8KB (For Parameter Storage); Built-In Real-Time Clock (RTC): Accuracy ±1s/Day (25℃); Support Parameter Power-Off Retention (≥10 Years); Clock Backup Power Supply: 3V CR2032 Button Battery, ensuring parameter and clock data are not lost after power off.
|
|
|
Protection & Alarm Parameters
|
Comprehensive Protection Functions
|
Electrical Protection: Overcurrent Protection, Overvoltage Protection, Undervoltage Protection, Short-Circuit Protection (Output Channels); Thermal Protection: Board Overheating Protection (Trigger Temperature: ≥85℃); Operational Protection: Signal Loss Protection, Power Supply Abnormality Protection, Input/Output Fault Protection.
|
|
Alarm Functions
|
Alarm Output: 2 Channels Relay Output (NO/NC Optional); Alarm Log: Store Up to 50 Sets of Alarm Records (Including Time, Alarm Code, Alarm Description); Alarm Indication: LED Indicator (Red for Fault, Green for Normal); Support Alarm Acknowledgment and Reset Functions, convenient for maintenance and troubleshooting.
|
|
|
Anti-Interference & Insulation
|
Anti-Electrostatic Discharge (ESD): ±25kV (Air), ±15kV (Contact); EMC Compliance: EN 55011 (Class B) Emission, EN 55022 (Class B) Immunity; Insulation Resistance: ≥1000MΩ (500V DC); Insulation Strength: 2.5kVrms (1 Minute), No Breakdown or Flashover.
|
|
|
Self-Check Function
|
Built-In Self-Check Module; Self-Check Items: Power Supply, Microcontroller, Signal Acquisition Circuit, Input/Output Circuit, Protection Circuit; Self-Check Result Output: Digital Signal (High Level: Normal, Low Level: Fault); Fault Code Display (Consistent with MEIDEN Official Fault Manual).
|
|
|
Control & Communication Parameters
|
Control Modes
|
Built-In Multiple Control Modes: Logic Control, Sequence Control, PID Control (Configurable); Support Manual/Auto Switching, Multi-Step Control (Up to 32 Steps); PID Parameter Adjustable (Proportional Band, Integral Time, Derivative Time), adapting to different industrial control scenarios.
|
|
Communication Interface
|
Standard Interface: RS485 (Modbus RTU Protocol); Data Transmission Rate: 9600~57600 bps (Adjustable); Communication Distance: ≤200m; Optional Interfaces: CANopen, Ethernet (RJ45, TCP/IP); Support Remote Parameter Setting, Data Reading and Fault Query, convenient for centralized control.
|
|
|
Input/Output Expansion
|
Support Input/Output Expansion via Expansion Bus; Maximum Expansion Capacity: 32 Digital Inputs / 32 Digital Outputs, 16 Analog Inputs / 16 Analog Outputs; Expansion Module Compatibility: MEIDEN Standard Expansion Modules (MSC-Series); Flexible expansion, adapting to different control scale requirements.
|
|
|
Parameter Setting
|
Support Parameter Configuration via MEIDEN Special Configuration Software (≥V3.80), External HMI or Communication Interface; 2-Level Password Protection; Support Parameter Backup and Restore; Configurable Parameters: Control Mode, Input/Output Type, Alarm Threshold, PID Parameters.
|
|
|
Environmental & Physical Parameters
|
Operating Environment
|
Operating Temperature: 0℃~50℃; Storage Temperature: -25℃~75℃; Operating Humidity: 20%~95% RH (Non-Condensing); Storage Humidity: <80% RH (Non-Condensing); Cooling Method: Natural Cooling / Forced Air Cooling (Optional); Protection Grade: IP20 (Cabinet Mounting), Dust-Proof and Anti-Splash.
|
|
Physical Dimensions
|
Overall Dimensions: 160mm × 120mm × 30mm (Length × Width × Height, ±0.5mm); Mounting Method: DIN Rail Mounting / Screw Mounting (Dual Optional); Weight: ≤300g (Without Accessories); Housing Material: High-Temperature Resistant FR-4 Epoxy Resin Board + Flame-Retardant Plastic Cover; Compact Structure, Easy to Install and Maintain.
|
|
|
Durability & Service Life
|
Vibration Resistance: 3g (10Hz~500Hz); Shock Resistance: 15g (11ms); Service Life: ≥50,000 Hours (Under Rated Working Conditions); Component Service Life: Microcontroller ≥100,000 Hours; Regular Maintenance Interval: Every 12 Months (Cleaning, Terminal Inspection).
|
1 .Our company specializes in automation industrial control accessories. We have more than 100,000 products.
Including : frequency converter, servo driver, servo motor, data acquisition card, industrial camera, touch screen, circuit board, DCS module, soft starter, industrial computer,encoder... etc
2,We accept PayPal transaction. All products provided 60 days warranty. We can send the goods by fast express to all over world.
3. We can supply the product in brand new or used condition to meet your requirement.The picture and price show on our store is not real, before purchasing, please contact us to provide you with accurate quotation and real pictures.
4. If you can not find the product you need in our store, please contact us .we will check it for you.