1 PCS USED NEWPORT Infinity Panel Meter INFCS-400B #LYQ007
1 PCS USED NEWPORT Infinity Panel Meter INFCS-400B #LYQ007
|
Parameter Category
|
Parameter Name
|
Original Factory Precision Specification
|
|
Basic Information
|
Product Model
|
INFCS-400B; NEWPORT (USA) Genuine Original Infinity Panel Meter, 100% unused and unrefurbished genuine parts, consistent with NEWPORT's official model coding standards. It belongs to high-precision industrial-grade panel meter, designed for dedicated matching with various industrial measurement and monitoring systems, with fixed configuration and excellent environmental adaptability, focusing on high-precision measurement, clear display and reliable data transmission.
|
|
Manufacturer Standard
|
Manufactured by NEWPORT Corporation (USA, Genuine Original Factory); Compliant with ISO 9001 Quality Certification, CE, RoHS, IEC 61010-1, ANSI/ISA 51.1 Industrial Standards; Conforms to NEWPORT Internal Technical Standard and Precision Panel Meter Manufacturing Norms, meeting the precision calibration requirements of international high-precision measurement equipment standards and related industrial monitoring specifications.
|
|
|
Core Measurement & Display Parameters
|
Meter Type
|
Digital Panel Meter; Infinity Series; High-Precision LCD Display; Multifunctional Measurement (Voltage, Current, Resistance Optional); Single-Channel Input; Built-in signal conditioning module, supporting multiple input signal types, high integration, reducing external circuit configuration.
|
|
Measurement Range (Voltage)
|
DC Voltage: 0 ~ 10V, 0 ~ 30V, 0 ~ 100V (Switchable); AC Voltage: 0 ~ 110V, 0 ~ 220V (Switchable); Tolerance: ±0.05% FS; High measurement precision, stable performance under rated working conditions, fully meeting industrial high-precision voltage measurement requirements; Test standard: IEC 61010-1.
|
|
|
Measurement Range (Current)
|
DC Current: 0 ~ 20mA, 0 ~ 100mA, 0 ~ 1A (Switchable); AC Current: 0 ~ 20mA, 0 ~ 1A, 0 ~ 10A (with Current Transformer); Tolerance: ±0.05% FS; Consistent with voltage measurement precision, ensuring accurate current data collection and display; Built-in current shunt (for low-range current).
|
|
|
Measurement Range (Resistance)
|
Optional: 0 ~ 1kΩ, 0 ~ 10kΩ, 0 ~ 100kΩ, 0 ~ 1MΩ (Switchable); Tolerance: ±0.1% FS; Suitable for low-resistance and medium-resistance measurement scenarios, stable measurement performance, no obvious drift.
|
|
|
Display Specifications
|
Display Type: High-Contrast LCD Display; Display Digits: 4.5 Digits (19999 Counts); Refresh Rate: 2 ~ 10Hz (Adjustable); Display Unit: V, A, Ω (Auto-Recognition); Backlight: White LED Backlight (Adjustable Brightness, Optional On/Off); Clear display under various light conditions, convenient for on-site observation.
|
|
|
Measurement Resolution
|
Voltage: 1mV (0 ~ 10V Range), 10mV (0 ~ 100V Range); Current: 1μA (0 ~ 20mA Range), 1mA (0 ~ 1A Range); Resistance: 0.1Ω (0 ~ 1kΩ Range), 1Ω (0 ~ 10kΩ Range); High resolution, ensuring accurate capture of small signal changes.
|
|
|
Input Impedance
|
Voltage Input: ≥1MΩ; Current Input: ≤100Ω; Resistance Input: ≥10MΩ; High input impedance for voltage measurement, reducing impact on measured circuit; Low input impedance for current measurement, ensuring measurement accuracy.
|
|
|
Zero Drift & Temperature Drift
|
Zero Drift: ≤5μV/℃ (DC Voltage Range); Temperature Drift: ≤0.005% FS/℃ (-10℃ ~ 60℃); Low drift performance, ensuring measurement accuracy under different temperature conditions, no frequent zero calibration required.
|
|
|
Control & Alarm Parameters
|
Alarm Functions
|
Dual-Setpoint Alarm (Upper Limit, Lower Limit); Alarm Output: 2 Channels Relay Output (NO/NC Optional); Alarm Hysteresis: 0.1% ~ 10% FS (Adjustable); Alarm Indication: LCD Backlight Flashing + Front Panel LED Indicator; Convenient for real-time monitoring of abnormal data, timely feedback of measurement status.
|
|
Control Functions
|
Built-in PID Control (Optional); Manual/Auto Control Switch; Control Output: 4 ~ 20mA Analog Output / Relay Output; Control Precision: ±0.1% FS; Suitable for closed-loop control scenarios, realizing automatic adjustment based on measurement data.
|
|
|
Parameter Setting
|
Front Panel Button Setting (3 Keys: Menu, Up, Down); Password Protection (Optional); Parameter Lock Function; Support Parameter Restoration to Factory Defaults; Simple operation, convenient for on-site parameter adjustment and management.
|
|
|
Data Hold & Peak Capture
|
Data Hold Function (Manual Trigger); Peak Capture Function (Auto Capture Max/Min Value); Hold Time: 1 ~ 999s (Adjustable); Convenient for capturing and recording key measurement data, improving on-site operation efficiency.
|
|
|
Interface & Power Parameters
|
Communication Interface
|
Standard Interface: RS485 (Modbus RTU); Optional Interface: RS232, Ethernet (RJ45); Data Transmission Rate: 9600 ~ 115200 bps (Adjustable); Supports Remote Parameter Setting and Data Reading; Easy to integrate into industrial automation control systems, compatible with various industrial control hosts.
|
|
Input/Output Interfaces
|
Analog Input: 1 Channel (Voltage/Current/Resistance, Switchable); Analog Output: 1 Channel (4 ~ 20mA DC, Optional); Digital Output: 2 Channels Relay Output (Alarm/Control); Optically Isolated Input/Output: 2.5kVrms; Strong anti-interference ability, protecting the device from external signal interference.
|
|
|
Power Supply
|
Power Supply Type: AC/DC Dual Power Supply; AC Input: 100 ~ 240V AC, 50/60Hz (Auto-Adaptation); DC Input: 24V DC (±10%); Power Consumption: ≤5W; Stable power supply adaptability, able to work normally under power grid voltage fluctuation, low power consumption, energy-saving and environmentally friendly.
|
|
|
Isolation Performance
|
Input to Output Isolation: ≥2.5kVrms; Input to Power Supply Isolation: ≥2.5kVrms; Output to Power Supply Isolation: ≥1kVrms; High isolation performance, effectively preventing voltage interference between circuits, ensuring device safety and measurement accuracy.
|
|
|
Environmental & Physical Parameters
|
Operating Environment
|
Operating Temperature: -10℃ ~ 60℃; Storage Temperature: -25℃ ~ 70℃; Operating Humidity: 10% ~ 90% RH (Non-Condensing); Storage Humidity: < 80% RH (Non-Condensing); Cooling Method: Natural Cooling; Protection Grade: IP54 (Front Panel), IP20 (Rear Terminal); Effectively preventing dust and water splashing, suitable for most industrial environments.
|
|
Physical Dimensions
|
Panel Cutout Dimensions: 96mm × 48mm (±0.1mm); Overall Dimensions: 100mm × 52mm × 120mm (Length × Width × Depth, ±0.5mm); Weight: ≤200g (Without Accessories); Housing Material: High-Temperature Resistant ABS Plastic (Flame-Retardant); Installation Method: Panel Mounting; Compact structure, easy to install and maintain.
|
|
|
Durability & Service Life
|
Electromagnetic Compatibility (EMC): Complies with EN 55011 (Class B) Emission, EN 55022 (Class B) Immunity; Vibration Resistance: 1g (10Hz ~ 500Hz); Shock Resistance: 10g (11ms); Service Life: ≥50,000 Hours (Under Rated Working Conditions); Long-term stable operation under harsh industrial environments, low failure rate; Button Service Life: ≥100,000 Times; LCD Service Life: ≥100,000 Hours.
|
1 .Our company specializes in automation industrial control accessories. We have more than 100,000 products.
Including : frequency converter, servo driver, servo motor, data acquisition card, industrial camera, touch screen, circuit board, DCS module, soft starter, industrial computer,encoder... etc
2,We accept PayPal transaction. All products provided 60 days warranty. We can send the goods by fast express to all over world.
3. We can supply the product in brand new or used condition to meet your requirement.The picture and price show on our store is not real, before purchasing, please contact us to provide you with accurate quotation and real pictures.
4. If you can not find the product you need in our store, please contact us .we will check it for you.