1 PCS used Azbil FRS100C250-2 Flame Controller#LYQ007
1 PCS used Azbil FRS100C250-2 Flame Controller#LYQ007
|
Parameter
|
Specification
|
Unit
|
Notes (Original Factory Description)
|
|
Brand
|
Azbil (Yamatake)
|
-
|
Genuine Azbil (Yamatake) Original Factory Production, 100% Authentic, Industrial-Grade High-Reliability Flame Controller[1][2]
|
|
Product Model
|
FRS100C250-2
|
-
|
Original Azbil Model, Factory Calibrated, No Modification, Belongs to FRS100 Series Flame Controllers, FRS100C Sub-Series[1][2]
|
|
Product Name
|
Flame Controller
|
-
|
Industrial-Grade Flame Monitoring and Control Device, Specialized for Burner, Furnace and Boiler Flame Safety Control[1][2]
|
|
Product Type
|
Industrial-Grade Flame Controller, Stand-Alone Type
|
-
|
Integrated Flame Detection, Ignition Detection and Signal Output Functions, Suitable for Harsh Industrial Combustion Scenarios[2]
|
|
Rated Supply Voltage
|
100 V AC, 200 V AC, 220 V AC (50/60 Hz); ±15% Voltage Tolerance
|
V AC, Hz
|
Multi-Voltage Adaptation, Compatible with Global Standard Industrial Power Supply Systems, Stable Power Operation[1]
|
|
Power Consumption
|
Max. 3 W (FRS100C Series Standard)
|
W
|
Low Power Consumption, Energy-Saving Design, Complies with Azbil Factory Electrical Safety Standards[1][2]
|
|
Flame Detection Type
|
Flame Voltage Detection, High-Sensitivity Signal Recognition
|
-
|
Optimized for Stable Flame Signal Capture, Strong Anti-Interference, Reducing False Alarm Rate[2]
|
|
Ignition Detection Level
|
Max. 1 V (Flame Voltage)
|
V
|
Precise Ignition Signal Detection, Ensuring Reliable Ignition Confirmation and Combustion Start-Up[2]
|
|
Flame-Out Detection Level
|
Min. 0.4 V (Flame Voltage, FRS100C Series)
|
V
|
Rapid Flame-Out Recognition, Timely Feedback to Ensure Combustion Safety[2]
|
|
Stable Flame Voltage
|
2.0 V DC or More (Stable Operation Requirement)
|
V DC
|
Ensures Continuous and Stable Flame Monitoring, Avoiding Misoperation Caused by Voltage Fluctuation[1][2]
|
|
Flame Signal Output
|
0 ~ 5 V DC; Output Terminals: A (-) and B (+) on Body
|
V DC
|
Standard Analog Signal Output, Compatible with External Control Equipment, Max. Wiring Distance: 10 m (Shielded Cable Required)[2]
|
|
External Equipment Input Impedance
|
Min. 100 kΩ
|
Ω
|
Required Input Impedance for Externally Connected Equipment, Ensuring Stable Signal Transmission[2]
|
|
Relay Output Capacity
|
250 VA (Terminal 3-4: Flame Output, 1k/2k); 250 VA (Terminal 3-8: Start Check Output, 1k)
|
VA
|
High-Capacity Relay Output, Directly Driving External Alarm and Control Devices, Stable and Reliable[1]
|
|
Operating Temperature Range
|
-20 ~ +60 °C (Single Unit Mounted); -20 ~ +45 °C (2+ Units Gang Mounted)
|
°C
|
Wide Temperature Adaptation, Stable Performance Under Different Mounting Conditions in Industrial Environments[2]
|
|
Storage Temperature Range
|
-40 ~ +85 °C
|
°C
|
Suitable for Long-Term Storage and Transportation in Extreme Temperature Conditions Without Performance Degradation[1][2]
|
|
Relative Humidity
|
0 ~ 90% RH (40 °C, Non-Condensing)
|
% RH
|
Strong Humidity Resistance, No Short Circuit Risk in High-Humidity Industrial Sites, Ensure Stable Operation[2]
|
|
Vibration Resistance
|
Max. 4.9 m/s², 10 ~ 60 Hz, 2 Hours Each in X, Y, Z Directions (Screw Mounted)
|
m/s², Hz
|
Strong Vibration Resistance, Adaptable to Industrial On-Site Vibration Environments[2]
|
|
Insulation Resistance
|
Min. 50 MΩ (Between Each Terminal and Ground, 500 V DC Megger)
|
MΩ
|
High Insulation Performance, Ensuring Electrical Safety in Industrial Operation[2]
|
|
Dielectric Strength
|
1500 V AC for 1 Min; 1800 V AC for 1 Sec (No Failure, Excluding Flame Detector Input Terminals ⑤ and ⑥)
|
V AC, Min, Sec
|
Excellent Dielectric Strength, Complying with Industrial Electrical Safety Standards[2]
|
|
Induction Lightning Surge
|
10 kV, 1.2 × 50 μs (Terminal ② and Ground, Surge Impedance Min. 75 Ω, With Recommended Surge Absorber)
|
kV, μs, Ω
|
Lightning Surge Protection, Recommended Surge Absorber: Specification Sheet No. 10013 (Part No.)[2]
|
|
Mounting Type
|
Stand-Alone Mounting; Gang Mounting (2+ Units)
|
-
|
Flexible Mounting Options, Adapting to Different On-Site Installation Requirements[1][2]
|
|
Wiring Requirement
|
Min. 0.75 mm² Wire; Shielded Cable Recommended for Flame Signal Wiring
|
mm²
|
Standard Wiring Specification, Ensuring Stable Signal Transmission and Device Reliability[1][2]
|
|
Certifications
|
IEC, EN, CE Certified (Compliant with Global Industrial Safety Standards)
|
-
|
Complies with International Industrial Safety and Quality Standards, Applicable to Global Industrial Combustion Scenarios[1][2]
|
|
Application
|
Industrial Burners, Furnaces, Boilers, Thermal Processing Equipment
|
-
|
Widely Used in Industrial Thermal Processing, Providing Precision Flame Monitoring and Safety Protection[1][2]
|
1 .Our company specializes in automation industrial control accessories. We have more than 100,000 products.
Including : frequency converter, servo driver, servo motor, data acquisition card, industrial camera, touch screen, circuit board, DCS module, soft starter, industrial computer,encoder... etc
2,We accept PayPal transaction. All products provided 60 days warranty. We can send the goods by fast express to all over world.
3. We can supply the product in brand new or used condition to meet your requirement.The picture and price show on our store is not real, before purchasing, please contact us to provide you with accurate quotation and real pictures.
4. If you can not find the product you need in our store, please contact us .we will check it for you.