1 PCS NEW KRIES Live Display CAPDIS-S2+ -R4.5 #LYQ007
1 PCS NEW KRIES Live Display CAPDIS-S2+ -R4.5 #LYQ007
|
Parameter Category
|
Parameter Name
|
CAPDIS-S2+ -R4.5 Specification
|
|
Basic Information
|
Product Model
|
CAPDIS-S2+ -R4.5; Genuine Original KRIES Live Display, 100% brand-new, unused and unrefurbished genuine parts; High-precision industrial electrical live status display component, integrated with live detection and status indication functions.
|
|
Manufacturer Standard
|
Complies with IEC 61243-5, EN 61243-5, DIN EN 60529 Standards; Conforms to KRIES internal technical and quality norms for live displays; Passes strict factory precision calibration and performance testing, ensuring compliance with industrial electrical safety standards.
|
|
|
Product Application
|
High-voltage Switchgear, Power Distribution Cabinets, Electrical Control Panels, Power Transmission Equipment, Industrial Power Distribution Rooms, Workshop Electrical Systems, High-rise Building Power Supply Systems, Power Transformation and Distribution Equipment, Electrical Safety Monitoring Scenarios.
|
|
|
Product Type
|
Industrial-grade Live Display; Integrated live detection and status indication, supporting stable operation in complex industrial electrical environments; Equipped with anti-interference and overvoltage protection functions, ensuring accurate live status feedback.
|
|
|
Core Detection Parameters
|
Rated Detection Voltage Range
|
AC 1kV ~ 40.5kV; Wide voltage detection range, suitable for most industrial high-voltage and medium-voltage live detection scenarios, matching mainstream power distribution system voltage levels.
|
|
Detection Accuracy
|
±2% (Rated Voltage Range); High detection accuracy, ensuring accurate identification of live status, avoiding false indication caused by voltage fluctuation, meeting industrial electrical safety monitoring requirements.
|
|
|
Response Time
|
≤ 30ms; Fast response, real-time capture of live status changes, timely feedback of electrical equipment live information, ensuring the safety of operation and maintenance personnel.
|
|
|
Detection Resolution
|
0.01kV; High resolution, capable of detecting tiny voltage changes, ensuring accurate indication even in low-voltage live scenarios, improving electrical safety monitoring precision.
|
|
|
Live Indication Threshold
|
≥ 80% of Rated Voltage (Indication On); ≤ 20% of Rated Voltage (Indication Off); Clear indication threshold, avoiding misindication caused by voltage instability, ensuring reliable live status prompt.
|
|
|
Insulation Detection Function
|
Built-in Insulation Detection; Real-time monitoring of insulation status between the display and electrical equipment, insulation resistance ≤ 10MΩ will trigger alarm indication, preventing safety hazards caused by insulation damage.
|
|
|
Long-term Stability
|
≤ 1% / Year; Excellent long-term stability, reducing calibration frequency and maintenance costs, suitable for long-term continuous monitoring of industrial power distribution systems.
|
|
|
Core Electrical Parameters
|
Rated Working Voltage
|
DC 24V ±10% (Standard); Optional AC/DC 110V ±10%, AC/DC 220V ±10%; Stable power supply design, suitable for different industrial power supply scenarios, ensuring consistent performance output.
|
|
Operating Current
|
≤ 50mA (Working Mode); ≤ 10μA (Standby Mode); Low power consumption design, reducing energy consumption, suitable for long-term continuous operation in power distribution cabinets.
|
|
|
Output Signal Type
|
Dry Contact Output (NO/NC Optional); Signal switching capacity: AC 250V / 5A, DC 30V / 5A; Compatible with mainstream electrical control systems and alarm devices, facilitating remote monitoring.
|
|
|
Insulation Resistance
|
≥ 1000MΩ (500V DC); Excellent insulation performance, preventing short circuit caused by insulation breakdown in high-voltage environments, ensuring safe operation of the display and electrical equipment.
|
|
|
Withstand Voltage
|
AC 2kV (1min, Between Live Parts and Shell); Can withstand instantaneous overvoltage impact in industrial electrical environments, avoiding damage caused by voltage spikes.
|
|
|
Anti-interference Performance
|
Complies with GB/T 14598.10, IEC 61000-4; Strong anti-electromagnetic interference and anti-voltage fluctuation ability, stable operation in complex industrial electrical environments without signal distortion.
|
|
|
Self-check Function
|
Built-in Automatic Self-check Function; Regular self-check of detection circuit and indication module, abnormal status will trigger fault indication, reducing maintenance workload and ensuring reliable operation.
|
|
|
Mechanical Parameters
|
Installation Type
|
Panel Mounting; Standard panel installation size, easy to install on switchgear and power distribution cabinet panels, compatible with standard industrial panel installation processes.
|
|
Dimensions (L×W×H)
|
80mm × 80mm × 35mm (Typical); Compact structural design, small installation space, suitable for narrow installation environments in power distribution cabinets and switchgear.
|
|
|
Weight
|
≤ 0.2kg (Net Weight); Light weight, does not increase the load of switchgear and power distribution cabinets, suitable for long-term stable installation.
|
|
|
Shell Material
|
High-temperature Resistant Engineering Plastics (PC+ABS); Flame-retardant, anti-corrosion and impact-resistant, suitable for harsh industrial environments, ensuring the integrity of internal components.
|
|
|
Indication Window
|
Transparent High-strength PC Material; High light transmittance, clear indication visibility, anti-scratch and anti-fog, ensuring clear observation of live status in various environments.
|
|
|
Wiring Terminal
|
Copper Alloy Terminal; Anti-oxidation, good electrical conductivity, compatible with 1.5mm² ~ 4mm² wires, easy to wire and fix, ensuring stable signal transmission.
|
|
|
Environmental & Protection Parameters
|
Operating Temperature Range
|
-25℃ ~ +70℃; Wide temperature adaptation range, stable operation in high and low temperature industrial environments, including outdoor power distribution rooms and cold storage supporting power systems.
|
|
Storage Temperature Range
|
-40℃ ~ +85℃; Stable storage performance, convenient for transportation and inventory; No performance degradation after long-term storage, suitable for batch storage of products.
|
|
|
Operating Humidity Range
|
0% ~ 95% RH (Non-condensing); Resists humid industrial environments, no short circuit or signal distortion caused by humidity, suitable for humid power distribution scenarios such as underground workshops.
|
|
|
Vibration Resistance
|
10 ~ 500Hz, 5g Amplitude; Resists mechanical vibration generated by industrial equipment operation, no parameter drift or internal component damage, ensuring stable operation in vibrating environments.
|
|
|
Shock Resistance
|
200m/s² (20g), 11ms; Resists mechanical impact during transportation and installation, ensuring product integrity and performance stability, reducing installation and transportation losses.
|
|
|
Protection Level
|
IP54; Dustproof and Waterproof, Protected against dust ingress and splashing water from all directions, suitable for harsh industrial sites and outdoor power distribution scenarios.
|
|
|
Service Life
|
≥ 80000 Operating Hours (Continuous Operation, Standard Working Conditions); Long service life, reducing maintenance costs and equipment downtime for long-term monitoring of power distribution systems.
|
|
|
Other Technical Parameters
|
Indication Color
|
Red (Live), Green (No Live), Yellow (Fault); Clear color distinction, easy to identify live status and fault information, ensuring intuitive observation by operation and maintenance personnel.
|
|
Compatibility
|
Perfectly Compatible with Various Industrial Switchgear, Power Distribution Cabinets, Electrical Control Systems and Alarm Devices; Matching with mainstream industrial power distribution equipment, facilitating system integration.
|
|
|
Factory Calibration
|
100% Factory Calibrated; Strict performance testing and precision calibration before leaving the factory, all parameters consistent with KRIES official specifications; Calibrated with professional high-voltage detection equipment to ensure detection accuracy.
|
|
|
Calibration Cycle
|
Recommended Calibration Cycle: 24 Months; Regular calibration ensures long-term measurement accuracy, adapting to high-precision electrical safety monitoring requirements in industrial scenarios.
|
|
|
Operating Pressure Range
|
80kPa ~ 120kPa (Atmospheric Pressure Range); Stable operation under normal atmospheric pressure and slight pressure fluctuation environments, suitable for most indoor and outdoor industrial scenarios.
|
1 .Our company specializes in automation industrial control accessories. We have more than 100,000 products.
Including : frequency converter, servo driver, servo motor, data acquisition card, industrial camera, touch screen, circuit board, DCS module, soft starter, industrial computer,encoder... etc
2,We accept PayPal transaction. All products provided 60 days warranty. We can send the goods by fast express to all over world.
3. We can supply the product in brand new or used condition to meet your requirement.The picture and price show on our store is not real, before purchasing, please contact us to provide you with accurate quotation and real pictures.
4. If you can not find the product you need in our store, please contact us .we will check it for you.