Part Number: F6D0-TI-Ex8.FF.CGS.ST; Model: F6D0-TI-Ex8.FF.CGS.ST; Product Name: Pepperl+Fuchs Safety Barrier Module (Explosion-Proof IO Module)
Brand: Pepperl+Fuchs (A Global Leader in Industrial Sensor and Explosion-Proof Automation Technology, Specializing in Intrinsically Safe Equipment, Safety Barriers, and Industrial Communication Modules)
Product Status: Original Industrial-Grade Product (In Stock for Hazardous Area Automation Projects); Product Category: Intrinsically Safe (IS) Digital IO Module, Designed for Explosive Environments with Foundation Fieldbus Communication
Core Application: Dedicated to hazardous area automation systems (Zone 0/1/2 for gas, Zone 21/22 for dust), serving as a safe interface between field instruments and control systems. Widely used in oil & gas, chemical, pharmaceutical, petrochemical, and coal mining industries to realize safe data acquisition and control signal transmission for field devices.
Core Features: Intrinsically Safe Protection Design; 8 Channels Digital Input/Output; Foundation Fieldbus (FF) Communication Support; Integrated CGS (Configuration & Diagnostic System); High Anti-Interference Performance; Hot-Swappable Capability; Industrial-Grade Durability for Harsh Environments.
2. Core Performance Specifications (Ta = 25℃, Unless Otherwise Specified)
2.1 IO Terminal Parameters
IO Type: 8 Channels Configurable Digital Input/Output (DI/DO), Selectable via Software; Input Mode: Optically Isolated Digital Input, Compatible with NPN/PNP Signals; Input Voltage Range: 18-30V DC (Nominal 24V DC).
Output Mode: Open Collector Digital Output; Max Switching Voltage: 30V DC; Max Switching Current: 0.5A per Channel (Resistive Load); Response Time: < 1ms (Input/Output); Isolation: 2.5kVrms Isolation Between Channels and Bus, Optically Isolated from Power Circuit.
Intrinsically Safe Parameters: Explosion-Proof Marking: Ex ia IIC T4 Ga (Suitable for Zone 0 Hazardous Areas); Maximum Open-Circuit Voltage (Uo): 28V DC; Maximum Short-Circuit Current (Io): 120mA; Maximum Power (Po): 1.3W; Compatible with Intrinsically Safe Field Devices Meeting EEx ia IIC T4 Standards.
2.2 Communication & Control Parameters
Communication Protocol: Foundation Fieldbus (FF) H1; Communication Speed: 31.25 kbps; Communication Interface: Twisted Pair (Shielded), Conforming to IEC 61158-2 Standard; Network Topology: Line, Tree, or Star (With Repeater).
Configuration Interface: Integrated CGS (Configuration & Diagnostic System) via FF Bus; Support for Remote Configuration and Parameter Tuning; Diagnostic Functions: Channel Fault Detection, Power Fault Alarm, Communication Fault Alert, with Real-Time Status Feedback.
Control Mode: Remote Control via FF Bus, Local Manual Control (Optional); Parameter Storage: Non-Volatile Memory (Retain Configuration Parameters After Power Off); Signal Filtering: Adjustable Digital Filter (0.1ms-10ms) to Suppress Interference.
3. Hardware Configuration & Mechanical Parameters
3.1 Hardware Configuration
Power Supply: Input Voltage: 24V DC ±10%; Rated Current: 150mA (Typical), 300mA (Maximum); Power Consumption: ≤7.2W (Normal Operation, Full Load);
Protective Functions: Overvoltage Protection (36V DC Max), Undervoltage Protection (15V DC Min), Short-Circuit Protection (Output Channels), Reverse Polarity Protection (Power Input), Anti-Static Protection (±8kV Contact, ±15kV Air);
Indicator Lights: Power Indicator (Green), Communication Status Indicator (Yellow), Channel Status Indicators (Green for Normal, Red for Fault), Explosion-Proof Status Indicator (Blue), Facilitating Real-Time Monitoring and Troubleshooting.
3.2 Mechanical & Installation Parameters
Dimensions (W × H × D): 45mm × 175mm × 120mm; Mounting Type: DIN Rail Mount (35mm Standard DIN Rail, Conforming to EN 50022 Standard);
Weight: ≤400g (Net Weight); Housing Material: Flame-Retardant Aluminum Alloy (Heat Dissipation & EMI Shielding), Conforming to UL 94 V-0 Standard; Protection Grade: IP20 (Indoor Cabinet Installation);
Terminal Type: Screw Terminals (For IO & Power Connections, M3 Screws, Anti-Loose Design); Connector Type: Shielded Plug-in Connectors (For FF Bus, Gold-Plated Contacts for Anti-Corrosion and Reliability).